|
" Engineering in Medicine : "
edited by Max Schaldach, Seymour Furman.
Document Type
|
:
|
BL
|
Record Number
|
:
|
735244
|
Doc. No
|
:
|
b555081
|
Main Entry
|
:
|
edited by Max Schaldach, Seymour Furman.
|
Title & Author
|
:
|
Engineering in Medicine : : Volume 1: Advances in Pacemaker Technology\ edited by Max Schaldach, Seymour Furman.
|
Publication Statement
|
:
|
Berlin, Heidelberg: Springer Berlin Heidelberg, 1975
|
ISBN
|
:
|
3642661874
|
|
:
|
: 3642661890
|
|
:
|
: 9783642661877
|
|
:
|
: 9783642661891
|
Contents
|
:
|
1 Principles and Techniques of Cardiac Pacing --;Clinical Requirements for Pacemaker Therapy --;Electrophysiological Aspects of Cardiac Stimulation --;Techniques of Permanent Pacemaker Implantation --;Pacemaker Electronic Circuits --;2 Clinical Experience with Various Pacing Techniques --;Results of Permanent Cardiac Stimulation Therapy --;Myocardial and Endocardial Pacing Systems --;An Appraisal --;Transvenous Atrial Synchronized Pacing --;Pacemaker Therapy as a New Possibility for the Diagnosis and Treatment of Carotid Sinus Syncope --;Temporary Cardiac Pacing --;Problems with Temporary and Permanent Pacing for Cardiac Arrhythmias without AV --;Block --;Clinical Complications Due to Pacemaker System Failures and Their Management --;3 Patient Management --;Transtelephone Pacemaker Monitoring --;Long-Term Cardiological Follow-Up Results --;Computer Applications for Monitoring of Pacemaker Patients --;4 Stimulation Electrodes --;Engineering Concepts of Pacemaker Electrodes --;The Significance of the Tissue Reaction around the Electrode on the Late Myocardial Threshold --;Studies of Short- and Long-Term Threshold Changes --;Electrochemical Aspects of Pacing Electrodes --;Endocardial Electrograms and Pacer Sensing --;5 Longevity and Pacemaker Power Sources --;Long-Life Pacemakers --;Electrochemical and Radioactive Power Sources for Cardiac Pacemakers --;The Statistical Reliability of Lithium --;Iodine Batteries --;A Long-Lived, Reliable, Rechargeable Cardiac Pacemaker --;Promethium and Plutonium as Fuels for Pacemaker Power Sources --;The Betavoltaic Pacemaker Power Source --;Design Criteria for Betavoltaic Nuclear Batteries --;Thermoelectric Conversion Systems for Nuclear-Powered Pacemakers --;Interpretation and Implementation of International Radiation Protection Standards for Cardiac Pacemakers in the USA --;6 Clinical Experience with Long-Life Pacemakers --;Progress in Pulse Generator Longevity Preliminary Results of the CPI Lithium Iodide Unit --;Clinical Experience with Nuclear-Powered Pacemakers (Plutonium-238) --;Clinical Experience with Nuclear-Powered Pacemakers (Promethium-147) --;Initial U.S. Experience with Promethium-147 Fueled Cardiac Pacemakers --;Benefits and Risks of Promethium Battery-Powered Pacemakers.
|
Abstract
|
:
|
After more than a decade of successful application of cardiac pace- makers in the therapy of cardiac rhythm disorders, technological and clinical experience has reached a level, at which a technical survey of this field should be of general interest and might promote the further improvement of pace- maker therapy.
|
Subject
|
:
|
Biomedical engineering.
|
Subject
|
:
|
Engineering.
|
LC Classification
|
:
|
R1.E358 1975
|
Added Entry
|
:
|
Max Schaldach
|
|
:
|
Seymour Furman
|
| |