" A Mass Spectrometry Study of Isotope Separation in the Laser Plume "


Document Type : Latin Dissertation
Language of Document : English
Record Number : 905396
Doc. No : TL7b34v9f8
Main Entry : Suen, Timothy Wu
Title & Author : A Mass Spectrometry Study of Isotope Separation in the Laser Plume\ Suen, Timothy WuMao, Samuel S; Greif, Ralph
College : UC Berkeley
Date : 2012
student score : 2012
Abstract : Accurate quantification of isotope ratios is critical for both preventing the development of illicit weapons programs in nuclear safeguards and identifying the source of smuggled material in nuclear forensics. While isotope analysis has traditionally been performed by mass spectrometry, the need for in situ measurements has prompted the development of optical techniques, such as laser-induced breakdown spectroscopy (LIBS) and laser ablation molecular isotopic spectrometry (LAMIS). These optical measurements rely on laser ablation for direct solid sampling, but several past studies have suggested that the distribution of isotopes in the ablation plume is not uniform.This study seeks to characterize isotope separation in the laser plume through the use of orthogonal-acceleration time-of-flight mass spectrometry. A silver foil was ablated with a Nd:YAG at 355 nm at an energy of 50 μJ with a spot size of 71 μm, for a fluence of 1.3 J/cm<sup>2</sup> and an irradiance of 250 MW/cm<sup>2</sup>. Flat-plate repellers were used to sample the plume, and a temporal profile of the ions was obtained by varying the time delay on the high-voltage pulse. A spatial profile along the axis of the plume was generated by changing the position of the sample, which yielded snapshots of the isotopic composition with time. In addition, the reflectron time-of-flight system was used as an energy filter in conjunction with the repellers to sample slices of the laser plasma orthogonal to the plume axis.Mass spectrometry of the plume revealed a fast ion distribution and a slow ion distribution. Measurements taken across the entire plume showed the fast <sup>109</sup>Ag ions slightly ahead in both space and time, causing the <sup>107</sup>Ag fraction to drop to 0.34 at 3 μs, 4 mm from the sample surface. Although measurements centered on the near side of the plume did not show isotope separation, the slow ions on the far side of the plume included much more <sup>109</sup>Ag than <sup>107</sup>Ag. In addition to examining the isotope content of the ablation plume, this study has developed a mass spectrometry characterization technique that may be useful for investigating chemical reactions during laser ablation.
Added Entry : Mao, Samuel S; Greif, Ralph
Added Entry : UC Berkeley
کپی لینک

پیشنهاد خرید
پیوستها
عنوان :
نام فایل :
نوع عام محتوا :
نوع ماده :
فرمت :
سایز :
عرض :
طول :
7b34v9f8_13668.pdf
7b34v9f8.pdf
پایان نامه لاتین
متن
application/pdf
10.15 MB
85
85
نظرسنجی
نظرسنجی منابع دیجیتال

1 - آیا از کیفیت منابع دیجیتال راضی هستید؟