" Vertical Macular Asymmetry Measures Derived From SD-OCT for Detection of Early Glaucoma. "


Document Type : AL
Record Number : 911178
Doc. No : LA79c0225n
Title & Author : Vertical Macular Asymmetry Measures Derived From SD-OCT for Detection of Early Glaucoma. [Article]\ Sharifipour, Farideh; Morales, Esteban; Lee, Ji Woong; Giaconi, JoAnn; Afifi, Abdelmonem A; Yu, Fei; Caprioli, Joseph; Nouri-Mahdavi, Kouros
Date : 2017
Title of Periodical : UCLA
Abstract : To test the hypothesis that vertical asymmetry in macular ganglion cell/inner plexiform layer (GCIPL) thickness can improve detection of early glaucoma.Sixty-nine normal eyes and 101 glaucoma eyes had macular imaging with spectral-domain optical coherence tomography (OCT; 200 × 200 cube). The resulting GCIPL thickness matrix was grouped into a 20 × 20 superpixel array and superior superpixels were compared to their inferior counterparts. A global asymmetry index (AI) was defined as the grand mean of the asymmetry ratios. To measure local asymmetry, the corresponding thickness measurements of three rows above and below the horizontal raphe were compared individually and in combinations. Global and local AIs were compared to the best-performing GCIPL thickness parameters with area under the receiver operating curves (AUC) and sensitivity/specificities.Age or axial length did not influence AIs in normal subjects (P ≥ 0.08). Global and local AIs were significantly higher in the glaucoma group compared to normal eyes. Minimum (AUC = 0.962, 95% confidence interval [CI]: 0.936-0.989) and inferotemporal thickness (AUC = 0.944, 95% CI: 0.910-0.977; P = 0.122) performed best for detection of early glaucoma. The AUC for global AI was 0.851 (95% CI: 0.792-0.909) compared to 0.916 (95% CI: 0.874-0.958) for the best local AI. Combining minimum or inferotemporal GCIPL thickness and the best local AI led to higher partial AUCs (0.088 and 0.085, 90% specificity, P = 0.120 and 0.130, respectively) than GCIPL thickness measures.Macular vertical thickness asymmetry measures did not perform better than sectoral or minimum GCIPL thickness for detection of early glaucoma. Combining local asymmetry parameters with the best sectoral GCIPL thickness measures enhanced this task.
کپی لینک

پیشنهاد خرید
پیوستها
عنوان :
نام فایل :
نوع عام محتوا :
نوع ماده :
فرمت :
سایز :
عرض :
طول :
79c0225n_11350.pdf
79c0225n.pdf
مقاله لاتین
متن
application/pdf
592.85 KB
85
85
نظرسنجی
نظرسنجی منابع دیجیتال

1 - آیا از کیفیت منابع دیجیتال راضی هستید؟