This page uses JavaScript and requires a JavaScript enabled browser.Your browser is not JavaScript enabled.
مرکز و کتابخانه مطالعات اسلامی به زبان های اروپایی
منو
درگاههای جستجو
مدارک
جستجوی پیشرفته
مرور
جستجو در سایر کتابخانه ها
مستندات
جستجوی پیشرفته
مرور
منابع دیجیتال
تمام متن
اصطلاحنامه
درختواره
پرسش و پاسخ
سوالات متداول
پرسش از کتابدار
پیگیری پرسش
ورود
ثبت نام
راهنما
خطا
رکورد قبلی
رکورد بعدی
"
Stopping house mice building infestations through exterior control
"
Knote, Charles E.
Document Type
:
AL
Record Number
:
942835
Doc. No
:
LA1rg3f1s2
Language of Document
:
English
Main Entry
:
Knote, Charles E.
Title & Author
:
Stopping house mice building infestations through exterior control [Article]\ Knote, Charles E.
Title of Periodical
:
Proceedings of the Vertebrate Pest Conference
Volume/ Issue Number
:
13
Date
:
1988
Abstract
:
The author describes problems of contamination of foodstuffs in warehouses by commensal rodents, noting that an estimated 95% of such contamination in the U.S. is due to house mice, rather than commensal rats. Other estimates have stated that between 80% and 98% of the food industry’s rodent problem is due to house mice. Pest control operators have often failed to deal with the issue of exterior mice’s ability to access the interior of such storage facility, but rather have concentrated control methods inside the building, rather than searching for the source of the infestation. A study of 7 food warehouses located in Missouri, Kentucky, and South Carolina over a period from 1980 through 1883 revealed the following: exterior house mice were present virtually year-round and were far more numerous than interior mice as shown by trap captures; exterior mice fed on adult insects and insect larvae as well as weed and grass seed; good interior control of mice prevented breeding of interior mice, so nearly all interior mice originated from exterior populations; some mice traveled >200 ft across closely-mowed grass or pavement to reach the warehouse; mice were rarely carried into the warehouse in shipments of palleted foodstuffs. Mouse-proofing specifications are listed, with the intent of showing that exclusion of mice is possible if attention to detail is carried out. PCOs should provide services to retrofit buildings to be mouse-proof, as building managers are seldom able or willing to make this effort. Exclusion should be undertaken in conjunction with use of control measure such as interior and exterior multi-catch traps, bait stations, and glue boards. Details of case histories of successful house mouse control are provided.
https://lib.clisel.com/site/catalogue/942835
کپی لینک
پیشنهاد خرید
پیوستها
عنوان :
نام فایل :
نوع عام محتوا :
نوع ماده :
فرمت :
سایز :
عرض :
طول :
1rg3f1s2_48460.pdf
1rg3f1s2.pdf
مقاله لاتین
متن
application/pdf
354.16 KB
85
85
نمایش
نظرسنجی
نظرسنجی منابع دیجیتال
1 - آیا از کیفیت منابع دیجیتال راضی هستید؟
X
کم
متوسط
زیاد
ذخیره
پاک کن